×

 

EN-13123-1 Shock tube test

EN-13123-2 Range test

 

Windows, doors and shutters - Explosion resistance - Requirements and classification 

 EN13123-1 is the European Standard which specifies the criteria that windows, doors and shutters shall satisfy to achieve a classification when submitted to the shock tube test method described in EN 13124-1.

To view products that can offer blast resistant properties, see the below links.

Stock items 

Bullet Resistant Transaction Window - Exterior / Interior Bullet Resistant Window with Electronic Speech, Ticket Window.

Night Pay Window / Hatch - A flat fronted Transaction Window with opening drawer, typically uses Petrol Stations and Pharmacies.

BR6  Guard House Transaction Window -Flat fronted Ballistic Window with opening drawer for document transfer. 

All of the above can also be manufactured in bespoke sizes.

Bespoke items 

Blast Resistant Glass -Laminated Blast resistant Glass to incorporate into Blast Windows and Doors                                                  

Blast Windows - Blast windows to protect against terrorist attacks and longer petrochemical explosions

Security Counters and Screens - Physical, Ballistic or Blast resisting counters for any application to keep staff secure.

Ballistic and Blast Resistant Guard Houses - Modular New Build or Upgrading existing. EN1522/3 FB2 to FB7, NIJ 0108.01 LII to IV UL 752.

Explosion Vents and Rupture Panels - Safety devices used to contain an explosive blast effect within a building.

Blast Resistant Doors - Steel manufactured doors offering blast protection to buildings

Shock tube extract from DIN EN 13123-1 & 13124-1

     Class Peak pressure (bar)* Positive specific impulse (i+) (bar-ms)
     EPR 1                    0,50                   3,7
     EPR 2                    1,00                   9,0
     EPR 3                    1,50                15,0
     EPR 4                     2,00                 22,0

* the duration greater than 20 ms

European Standard EN13123-2 specifies the criteria which windows, doors and shutters shall satisfy to achieve a classification when submitted to the range test method described in EN 13124-2.

This European Standard concerns a test method against blast waves in open air resulting from high explosives that can be carried by hand and placed a few metres from a target.  At such close distances blast values vary across an attack face.  Controlled measurement of the actual blast on the face of the test specimen being difficult, costly and subject to inaccuracy, consistency of the blast forces is therefore controlled in this European Standard by the characteristics of the explosive charge and its location.

This European Standard covers only the behaviour of the complete unit including infill, frame and fixings as tested.

It gives no information on the ability of the surrounding wall or building structure to resist the direct or transmitted forces.

If the windows, doors and shutters are intended for specific conditions of climate, specific test conditions can be required (see clause 4).

This European Standard gives no information on the explosion resistance capacity of the wall or other surrounding structure.

Open range extract from DIN EN 13123-2 & 13124-2

   Class  Charge Mass (kg) Standoff Distance(m) Charge Height (mm)
EXR1            3         5        500 + 50
EXR2           3         3        500 + 50
EXR3        12       5.5        800 + 50
EXR4        12       4        800 + 50
EXR5        20      4        800 + 50

 (Splinters / No Splinters)

 

 

For our full range of technical specifications please click on relevant headings below;

 Other Blast Specifications

GSA-TS01:2003     Standard Test Method for Glazing and Window Systems Subject to Dynamic Overpressure Loadings

EN 13541                   Glass in building - Security glazing - Testing and classification of resistance against explosion pressure 

ISO 16933:2007  Glass in Building -- Explosion-Resistant Security Glazing -- Test & Classification for Arena Air-Blast Loading

Ballistic Technical Specifications

EN 1063               Glass in Building - Security Glazing - Testing and Classification of Resistance Against Bullet Attack

UL 752                   Standard for Bullet-Resisting Equipment

BS 5051                Bullet-resistant glazing - Part 1:  for interior use- Part 2: for Exterior use

NIJ 0108.01      US National Institute of Justice Standard-Test and Certification for Ballistic Resistant Materials

EN 1522/3          Windows, doors, shutters and blinds - Bullet resistance - Requirements and classification / Test method

Fire Specifications

UL 10C           Positive Fire Pressure Tests of Door Assemblies 

EN 1363-1    Fire resistance tests –Part 1: General Requirements

EN 1364-1     Fire resistance tests for non-load-bearing elements – Part 1: Walls

BS 476 Part 22     Fire tests on building materials and structures

EN 1634-1   Fire resistance and smoke control tests for door and shutter assemblies, openable windows and elements of building hardware 

Attack Specifications

EN 1627   Pedestrian door-sets, windows, curtain walling, grilles and shutters - Burglar resistance - Requirements and classification

LPS 1270   Requirements& testing procedures for the LPCB approval & Listing of intruder resistant security glazing unit

EN 356         Glass in building - Security glazing - Testing and classification of resistance against manual attack.

 

This is an extract not a full report and Architectural Armour Ltd accepts no liability for any loss, direct, indirect or consequential damage incurred by using this information, to the fullest extent permitted by law. You should make your own judgement as regards use of this document and seek out the full test standards.

Latest News

Split Height Transaction Window Duo 

Using experience on previous projects and customers requirements we have designed a split height transaction window offering standing and DDA access to reception and data centre environments.

2 Position Screen

 

For more information and pricing please contact our office on info@architecturalarmour.com or +44(0)1981 257000

 

 

Read more

Increased Stock for Express Delivery

We have increased our range of stock transaction windows to six units , ready for express dispatch.

Our range of transaction windows include, physical attack resistant and bullet resistant internal and external models. Please see below an outline of our products.

Architectural Armour are offering standard stock items and bespoke orders to suit.  Please contact us on +44(0) 1981 257000 

 

 

Stock Transaction Windows

 

 

 

 

 

 

 

 

 

 

 

 

Read more