Fire iconFire Resistant Glass

Architectural Armour offer a wide range of fire-resistant glass with either stand alone fire glass or more complex constructions offering protection from physical attack to bullet resistant to suit your security and fire rated needs.

If your requirement is for a complete window please visit Fire Resistant Windows

 

Fire Test on Glass

 

Protection Levels

When referring to fire rated glazing there are a number of terms, qualities to the glass that can be provided.  These are subdivided into protection levels.

Protection levels are measured in defined time periods of 30, 60, 90, 120 and 180 minutes and in terms of either integrity, integrity and insulation or Integrity and Radiation, as designated by the British & European Standards.

Integrity (E)

Integrity, meaning the glazing can withstand the designated minutes against the flames and hot gases penetrating through to the unexposed glass face, i.e. if no flames or hot gases occurred on the non fire side before 1 hour it would be E60 rated.

Radiation(EW)

Radiation and Integrity means the glass offers protection against flames (E) but also the heat that emits from the flame.  Heat radiation through to the non exposed side should remain below temperatures sets by the standards. value of 15kW/m2 reducing the radiated heat to other materials and people.

Insulation(EI)

Integrity and Insulation means the glass has the above qualities of (E)with the additional property of reducing the temperature rise on the non exposed glass face, to below temperatures sets by the standards.

 

 

 

 

 

 

Fire Rated Security Glass

In addition the stand alone fire glass, Architectural Armour can offer Ballsitic / Bulletproof and Physical Attack rated fire glass. By introducing a fire rated glass in the lamination process both bullet resistant and physical attack glass can offer E30 and E60 fire protection.

Bullet Resistant Security Glass

Bullet resistant glass is available in spall allowed and no spall , both of these options are available in E30 and £60 . Below we list the thicknesses of the EN1063 bullet rated fire glass. Spall Allowed which are all glass constructions can be offered with multi-directional fire protection;  two pieces of fire rated glass are laminated to the construction, the first and last layer enabling protection from both sides.

EN 1063 Bullet Resistant Spall Allowed Fire Glass

 

Ballistic Fire Glass E30 (using 630 Pyrotech) & E60 (using 660 Pyrotech)

SPALL ALLOWED

 PDF

     

BS EN 1063 BR2 E30 & E60

38 mm thick

 br2 fire glass

BS EN 1063 BR3 E30 & E60

41 mm thick

  br3 spall allowed fire glass

BS EN 1063 BR4 E30 & E60

48 mm thick

 br4 spall allowed fire glass

BS EN 1063 BR5 E30 & E60

52 mm thick 

br5 spall allowed fire glass

BS EN 1063 BR6 E30 & E60

67 mm thick

 br6 spall allowed fire glass

BS EN 1063 BR7 E30 & E60

92 mm thick 

br7 spall allowed fire glass

BS EN 1063 SG1 E30 & E60

50 mm thick 

sg1 spall allowed fire glass

BS EN 1063 SG2 E30 & E60

61 mm thick  sg1 fire glass spall allowed

AK47 E30 & E60

51 mm thick

   

 

EN 1063 Bullet Resistant NO Spall Fire Glass

  
Ballistic Fire Glass E30 (using 630 Pyrotech) & E60 (using 660 Pyrotech) NO SPALL  PDF
     
BS EN 1063 BR2 E30 & E60 27 mm thick br2 no spall fire rated glass
BS EN 1063 BR3 E30 & E60 27 mm thick br3 no spall fire rated glass
BS EN 1063 BR4 E30 & E60 33 mm thick  br4 no spall fire rated glass
BS EN 1063 BR5 E30 & E60 42 mm thick  br5 no spall fire rated glass
BS EN 1063 BR6 E30 & E60 50 mm thick br6 no spall fire rated glass
BS EN 1063 BR7 E30 & E60 75 mm thick   br7 no spall fire rated glass
BS EN 1063 SG1 E30 & E60 33mm thick   sg1 no spall fire rated glass
BS EN 1063 SG2 E30 & E60 42mm thick    sg2 no spall fire rated glass
 

 

Attack Resistant Fire Glass Available

 

Fire Rated Attack Resistant Glass E30(using 630 Pyrotech) & E60 (using 660 Pyrotech)

Thickness

Weight (kg/m2)

PDF

Fire Rated Intruder Resistant Glass E30(using 630 Pyrotech) & E60 (using 660 Pyrotech)

Thickness

Weight (kg/m2)

BS EN 356 P4A E30 & E60

12.5 mm 

26

 

LPS 1270 001 E30 & E60

17mm

34

BS EN 356 P5A E30 & E60

14.5 mm 

31

 

LPS 1270 012 E30 & E60

21mm

39

BS EN 356 P7B E30 & E60

16.5 mm 

34

p7b en356 e30 and e60 glass image

LPS 1270 013 E30 & E60

23mm

42

BS EN 356 P8B E30 & E60

18.5 mm 

37

p8b en356 e30 and e60 glass image

LPS 1270 123 E30 & E60

27mm

46

BS EN 356 P8B E30 & E60

22.5 mm

45

p8b en356 e30 and e60 glass image

LPS 1270 113 E30 & E60

34mm

60

 

 

   

LPS 1270 224 E30 & E60

42mm

72

 

 

   

LPS 1270 234 E30 & E60

45mm

69

 

 

   

LPS 1270 235 E30 & E60

60mm

100

 

Our products can be sealed into a DGU/IGU for external use.  For  more information and to discuss your requirements please contact our team on +44 (0) 1981 257000 or email mailto:info@architecturalarmour.com 

Bespoke items with Glass

Fire Resistant Windows                                  Available as fire rated only or combined with our bullet, attack or blast windows.                  

Security Counters and Screens                   Physical, Ballistic or Blast resisting counters for any application to keep staff secure

Security Fire Doors                                           A combination of fire protection and security rated doors made to measure.

Fire Specifications

UL 10C           Positive Fire Pressure Tests of Door Assemblies 

EN 1363-1    Fire resistance tests –Part 1: General Requirements

EN 1364-1     Fire resistance tests for non-load-bearing elements – Part 1: Walls

BS 476 Part 22     Fire tests on building materials and structures

EN 1634-1   Fire resistance and smoke control tests for door and shutter assemblies, openable windows and elements of building hardware 

 

 

 

Latest News

Armoury Security

Architectural Armour were commissioned to provide ballistic resistant products for a new armoury at a UK International Airport.

                   Armoury handgun and ammunition pass through hatch  Ballistic Armoury Doors  Ballistic Armoury Drawer. for wepons transfer.j

Read more

London Bureau De Change Attack

We read it all the time in the news headlines, multiple attackers arrive on stolen mopeds, dressed in black with helmets covering their faces smashing their way through glass shopfronts and glazed screens.

                Bureau de Change London Attacked Glass        Bureau de Change counter & screen

Read more