EN 1634-1

Fire resistance and smoke control tests for door and shutter assemblies, openable windows and elements of building hardware - Part 1: Fire resistance test for door and shutter assemblies and openable windows

 Fire resistance and smoke control tests for door and shutter assemblies, openable windows and elements of building hardware - Part 1: Fire resistance test for door and shutter assemblies and openable windows

This European Standard specifies a method for determining the fire resistance of door and shutter assemblies and openable windows designed for installation within openings incorporated in vertical separating elements, such as:

a) hinged and pivoted doors;

b) horizontally sliding and vertically sliding doors including articulated sliding doors and sectional doors;

c) folding doors, sliding folding doors /shutters;

d) tilting doors;

e) rolling shutter doors;

f) openable windows;

g) operable fabric curtains.

This European Standard is used in conjunction with EN 1363-1.

The testing of fire dampers is covered by EN 1366-2.

The testing of closures for conveyor systems is covered by EN 1366-7

 By prior agreement with the test sponsor, additional information may be gained for individual elements of building hardware in order to fulfil the performance criteria identified in EN 1634-2.  Based on the observations recorded during the test, the results may be presented in a separate report which should be in accordance with the requirements of EN 1634-2.

Architectural Armour offer a range of fire rated products  to different standards, please click the relevant link below to find out more 

Fire Rated Products

Security Counters and Screens Physical, Ballistic or Blast resisting counters for any application to keep staff secure

Fire Windows   Available as fire rated only or combined with our bullet, attack or blast windows.

Fire Resistant Doors A combination of fire protection and security rated doors made to measure.

Fire Resistant Glass E30 to EI120 , Physical and Ballistic options available

 

For our full range of technical specifications please click on relevant headings below

 

Other Ballistic Technical Specifications

EN 1063               Glass in Building - Security Glazing - Testing and Classification of Resistance Against Bullet Attack

UL 752                   Standard for Bullet-Resisting Equipment

BS 5051                Bullet-resistant glazing - Part 1:  for interior use- Part 2: for Exterior use

NIJ 0108.01      US National Institute of Justice Standard-Test and Certification for Ballistic Resistant Materials

EN 1522/3          Windows, doors, shutters and blinds - Bullet resistance - Requirements and classification /Test method

Blast Specifications

GSA-TS01:2003     Standard Test Method for Glazing and Window Systems Subject to Dynamic Overpressure Loadings

EN 13541                   Glass in building - Security glazing - Testing and classification of resistance against explosion pressure 

EN 13123-2               Windows, doors and shutters - Explosion resistance - Requirements and classification

ISO 16933:2007  Glass in Building -- Explosion-Resistant Security Glazing -- Test & Classification for Arena Air-Blast Loading

Fire Specifications

UL 10C           Positive Fire Pressure Tests of Door Assemblies 

EN 1363-1    Fire resistance tests –Part 1: General Requirements

EN 1364-1     Fire resistance tests for non-load-bearing elements – Part 1: Walls

BS 476 Part 22     Fire tests on building materials and structures

Manual Attack  Specifications

EN 1627   Pedestrian door-sets, windows, curtain walling, grilles and shutters - Burglar resistance - Requirements and classification

LPS 1270   Intruder Resistant Security Glazing -  Requirements & Testing Procedures 

LPS 1175 Requirements and testing procedures for the LPCB certification and listing of intruder resistant building components, strongpoints, security enclosures and free-standing barriers

EN 356         Glass in building - Security glazing - Testing and classification of resistance against manual attack.

LPS 1175 and 1270 Tool Categories   Testing procedures for the LPCB approval

This is an extract not a full report and Architectural Armour Ltd accepts no liability for any loss, direct, indirect or consequential damage incurred by using this information, to the fullest extent permitted by law. You should make your own judgement as regards use of this document and seek out the full test standards. 

 

 

 

Fire Test DoorWarrington Fire Test of Bullet Resistant Timber Door

 

 

 

Latest News

Split Height Transaction Window Duo 

Using experience on previous projects and customers requirements we have designed a split height transaction window offering standing and DDA access to reception and data centre environments.

2 Position Screen

 

For more information and pricing please contact our office on info@architecturalarmour.com or +44(0)1981 257000

 

 

Read more

Increased Stock for Express Delivery

We have increased our range of stock transaction windows to six units , ready for express dispatch.

Our range of transaction windows include, physical attack resistant and bullet resistant internal and external models. Please see below an outline of our products.

Architectural Armour are offering standard stock items and bespoke orders to suit.  Please contact us on +44(0) 1981 257000 

 

 

Stock Transaction Windows

 

 

 

 

 

 

 

 

 

 

 

 

Read more