EN 1627

Pedestrian door-sets, windows, curtain walling, grilles and shutters - Burglar resistance - Requirements and classification

This European Standard specifies requirements and classification systems for burglar resistant characteristics of pedestrian door-sets, windows, curtain walling, grilles and shutters. It is applicable to the following means of opening: Turning, tilting, folding, turn-tilting, top or bottom hung, sliding (horizontally and vertically) and rolling as well as fixed constructions.  It also covers products that include items such as letter plates or ventilation grilles.  It specifies requirements for the burglar resistance of a construction product (as defined in 3.1 of this standard).

This European Standard does not directly cover the resistance of locks and cylinders to attack with picking tools.  It also does not cover precast concrete elements.

It also does not cover the attack of electric, electronic and electromagnetic operated burglar resistant construction products using attack methods that might defeat these characteristics.

NOTE 1 The mechanical parts of electric, electronic and electromagnetic operated burglar resistant construction products may be tested in electrical powerless condition.

This European Standard does not apply to doors, gates and barriers, intended for installation in areas in the reach of persons, and for which the main intended uses are giving safe access for goods and vehicles accompanied or driven by persons in industrial, commercial or residential premises, as covered by EN 13241-1.

NOTE 2 Construction products that can be reached or driven through by vehicles should be protected by appropriate measures such as barriers, extensible ramps, etc.

 

 

 

 

For our full range of technical specifications please click on relevant headings below;

Other Attack Specifications

LPS 1270   Intruder Resistant Security Glazing -  Requirements & Testing Procedures 

LPS 1175 Requirements and testing procedures for the LPCB certification and listing of intruder resistant building components, strongpoints, security enclosures and free-standing barriers

EN 356         Glass in building - Security glazing - Testing and classification of resistance against manual attack.

Other Ballistic Technical Specifications

EN 1063               Glass in Building - Security Glazing - Testing and Classification of Resistance Against Bullet Attack

UL 752                   Standard for Bullet-Resisting Equipment

BS 5051                Bullet-resistant glazing - Part 1:  for interior use- Part 2: for Exterior use

NIJ 0108.01      US National Institute of Justice Standard-Test and Certification for Ballistic Resistant Materials

EN 1522/3          Windows, doors, shutters and blinds - Bullet resistance - Requirements and classification /Test method

Blast Specifications

GSA-TS01:2003     Standard Test Method for Glazing and Window Systems Subject to Dynamic Overpressure Loadings

EN 13541                   Glass in building - Security glazing - Testing and classification of resistance against explosion pressure 

EN 13123-2               Windows, doors and shutters - Explosion resistance - Requirements and classification

ISO 16933:2007  Glass in Building -- Explosion-Resistant Security Glazing -- Test & Classification for Arena Air-Blast Loading

Fire Specifications

UL 10C           Positive Fire Pressure Tests of Door Assemblies 

EN 1363-1    Fire resistance tests –Part 1: General Requirements

EN 1364-1     Fire resistance tests for non-load-bearing elements – Part 1: Walls

BS 476 Part 22     Fire tests on building materials and structures

EN 1634-1   Fire resistance and smoke control tests for door and shutter assemblies, openable windows and elements of building hardware 

This is an extract not a full report and Architectural Armour Ltd accepts no liability for any loss, direct, indirect or consequential damage incurred by using this information, to the fullest extent permitted by law. You should make your own judgement as regards use of this document and seek out the full test standards. 

 

Latest News

Split Height Transaction Window Duo 

Using experience on previous projects and customers requirements we have designed a split height transaction window offering standing and DDA access to reception and data centre environments.

2 Position Screen

 

For more information and pricing please contact our office on info@architecturalarmour.com or +44(0)1981 257000

 

 

Read more

Increased Stock for Express Delivery

We have increased our range of stock transaction windows to six units , ready for express dispatch.

Our range of transaction windows include, physical attack resistant and bullet resistant internal and external models. Please see below an outline of our products.

Architectural Armour are offering standard stock items and bespoke orders to suit.  Please contact us on +44(0) 1981 257000 

 

 

Stock Transaction Windows

 

 

 

 

 

 

 

 

 

 

 

 

Read more